Clean your non free flow auger filler

How to Disassemble and Clean Your Non-Free Flow Auger Fille

March 10, 20252 min read

Keeping your auger filler parts clean is essential for sanitation and plays a crucial role in making parts lasting longer. I am going to delve into how disassemble your non free flow auger filler for cleaning. We will cover how to clean your free flow auger filler here: imagefillers.com/free-flow-cleaning.

Here is a nom free flow tooling diagram that shows all the parts we will go over.

Clean your non free flow auger filler

Step 1: Turn off the machine

Turn off the main disconnect to the machine located on the back control box.

Power off on auger filler

Step 2: Take off the funnel

There are 6 total thumb bolts on the coupling. The bottom 3 thumb bolts need to be loosened and then slide out the funnel.

Clean your non free flow auger filler

Step 3: Remove the auger

The auger is spring loaded so you need to push it up first into the spring, then rotate it counterclockwise, then down and out of the auger shaft. The spring loaded mechanism is shown below.

Clean your non free flow auger filler

Step 4: Remove the hopper

First remove the 4 quick release clamps at the top of the hopper.

Clean your non free flow auger filler

Remove the horizontal alignment bolt. Don't touch the 2 vertical alignments bolts because they are already set with proper alignment. Remove the hopper.

Clean your non free flow auger filler

Step 5: Remove the auger shaft and agitation blade

There is a bolt on both the auger shaft and agitation blade that needs to be removed to take off these two pieces of tooling.

Clean your non free flow auger filler

Clean your non free flow auger filler

Step 6: Clean everything

All the parts that we remove are stainless steel so wash accordingly. Usually just soap and water is necessary for cleaning.

Step 7: Reassemble the auger filler

Reassemble everything the same way your removed it.

  1. Reattach the auger shaft and agitation blade.

  2. Reattach the hopper, horizontal alignment bolt, and quick release clamps.

  3. Insert the auger into the auger shaft by pushing it up turn it clockwise until it stops and it should lock into place.

  4. Reattach the funnel until it fits snug into the coupling and then tighten the 3 bottom thumb bolts.

⚠️ The auger shaft and auger have to be set correctly before filling. If you want to learn how to do this go check out our auger alignment article here: Imagefillers.com/auger-alignment